How to change DTU to AT mode?

Admin
Admin 这家伙很懒,还没有设置简介

0 人点赞了该文章 · 2973 浏览

  Enter Advanced config mode:
DTU1.jpg
Enter Multi-center mechanism:
DTU2.jpg
Change Max reconnect interval vaule to : troy
DTU3.jpg
 Save config,reboot DTU.   Troy mode SIM Light and STATUS Light flash alternately.   Now you can sand AT command  through COM 1.       Exit at mode. After entering at mode, the serial port is always connected to the module, so it is unable to log in DTU directly with configuration tool to read / download configuration and other operations. If you want to connect DTU with configuration tool, you need to connect to COM2; or connect PC with serial port, press ESC key of keyboard / send exit with serial port tool.   退出AT模式。进入AT模式后,串口一直连模块,无法直接用配置工具登陆DTU读取/下载配置等操作。如果想用配置工具连DTU需要接到串口2;或者用串口一接pc,按键盘的ESC键/用串口工具发送exit.

发布于 2020-02-20 14:00

免责声明:

本文由 Admin 原创发布于 技术社区 ,著作权归作者所有。

登录一下,更多精彩内容等你发现,贡献精彩回答,参与评论互动

登录! 还没有账号?去注册

暂无评论

推荐内容

Windows Server系统无法打开数据中心测试工具的问题
DTU Ping功能如何使用?
DTU常见基础知识
RTool 远程管理DTU
DTU如何在低功耗下,正常收发数据?
DTU加密流程指南
如何打开外置式DTU外盖
双卡DTU的sim卡切换机制?
DTU配置 55AA指令
DTU连接南瑞主站登陆帧配置